Standard & Material:
Standards |
ASTMA519 |
DIN1629 |
|
|
|||
Materials/Grade |
1030 |
St37.0 |
|
1035 |
St44.0 |
|
|
1040 |
St52.0 |
|
|
1045 |
|
|
|
4130 |
|
|
|
4135 |
|
|
|
4140 |
|
|
|
4145 |
|
|
Mechanical Pipe Size Range:114.0~710.0mm, Wall thickness:6.0~70.0mm. Chemical Composition Limits,%,as per ASTM A519
Grade |
C |
Mn |
P |
S |
Si |
Ni |
Cr |
Mo |
1030 |
0.28-0.34 |
0.60-0.90 |
0.040 |
0.05 |
|
|
|
|
1035 |
0.32-0.38 |
0.60-0.90 |
0.040 |
0.05 |
|
|
|
|
1040 |
0.37-0.44 |
0.60-0.90 |
0.040 |
0.05 |
|
|
|
|
1045 |
0.43-0.50 |
0.60-0.90 |
0.040 |
0.05 |
|
|
|
|
4130 |
0.28-0.33 |
0.40-0.60 |
0.040 |
0.04 |
0.15-0.35 |
|
0.80-1.10 |
0.15-0.25 |
4135 |
0.33-0.38 |
0.70-0.90 |
0.040 |
0.04 |
0.15-0.35 |
|
0.80-1.10 |
0.15-0.25 |
4140 |
0.38-0.43 |
0.75-1.00 |
0.040 |
0.04 |
0.15-0.35 |
|
0.80-1.10 |
0.15-0.25 |
4145 |
0.42-0.48 |
0.75-1.00 |
0.040 |
0.04 |
0.15-0.35 |
|
0.80-1.10 |
0.15-0.25 |
The purchaser may specify the following maximum amounts:copper,0.3%;aluminum,0.05%;and oxygen,0.0015% Typcal Tensile Properties,Hardness and Thermal Condation for some the More Common Carbon and Alloy steels Gr
Grade Designation |
ConditionA |
Ultimate Strength |
Yield Strength |
Elongation in 2 in,or 50 mm,% |
Rockwell HardnessB scale |
||
Ksi |
Mpa |
Ksi |
Mpa |
||||
1035 |
HR |
65 |
448 |
40 |
276 |
20 |
72 |
CW |
85 |
586 |
75 |
517 |
5 |
88 |
|
SR |
75 |
517 |
65 |
448 |
8 |
80 |
|
A |
60 |
414 |
33 |
228 |
25 |
67 |
|
N |
65 |
448 |
40 |
276 |
20 |
72 |
|
1405 |
HR |
75 |
517 |
45 |
310 |
15 |
80 |
CW |
90 |
621 |
80 |
552 |
5 |
90 |
|
SR |
80 |
552 |
70 |
483 |
8 |
85 |
|
A |
65 |
448 |
35 |
241 |
20 |
72 |
|
N |
75 |
517 |
48 |
331 |
15 |
80 |
|
4130 |
HR |
90 |
621 |
70 |
483 |
20 |
89 |
SR |
105 |
724 |
85 |
586 |
10 |
95 |
|
A |
75 |
517 |
55 |
379 |
30 |
81 |
|
N |
90 |
621 |
60 |
414 |
20 |
89 |
|
4140 |
HR |
120 |
855 |
90 |
621 |
15 |
100 |
SR |
120 |
855 |
100 |
689 |
10 |
100 |
|
A |
80 |
552 |
60 |
414 |
25 |
85 |
|
N |
120 |
855 |
90 |
621 |
20 |
100 |
Wall thicness tolerances may not be allicable to walls 0.199 in.(5.05mm) and less;consult manufacturer for wall tolerances on such sizes Wall Thickness Tolerances for round Hot-Finished Tubing
Wall Thickness Range as Percent of Outside Diameter |
Wall Thickness Tolerance,APercent Over and Under Nominal |
|
|
|
|||
Outside Diameter |
Outside Diameter |
|
|
|
|||
3.000 in.(76.20mm)to 5.999 in.(152.37mm) |
6.000in.(152.40mm) to10.750 in.(273.05mm) |
|
|
|
|||
|
|||
|
|||
Under15 15 and over |
10.0 7.5 |
10.0 10.0 |
|
|
Wall thicness tolerances may not be allicable to walls 0.199 in.(5.05mm) and less;consult manufacturer for wall tolerances on such sizes